Image

Hydrostatic level probes

Any measurement range from 1 up to 500 m H2O
Integrated internal overvoltager protection circuit
Marine certificate DNV
ATEX Intrinsic safety
Output signal 4 ÷ 20 mA, two wire transmission

Image
Hydrostatic level probes for measurement of waste liquid levels
Any measurement range from 2 up to 20 m H2O
Integrated internal overvoltage protection circuit
ATEX Intrinsic safety Marine certificate DNV
Output signal 4 ÷ 20 mA, two wire transmission
Accuracy 0,075% (0,05% on request)

Image

SMART LEVEL PROBE FOR PRESSURE TANKS

Tank depth up to 6 m
Accuracy 0.16%
4...20 mA output signal + Hart
Intrinsic safety certificate (ATEX, IECEx)
Explosion proof certificate (ATEX, IECEx)
Accuracy 0,075% (0,05% on request)

Image

Level switch type ERH

Đặc tính kỹ thuật

Explosion proof version
Wetted parts material 316LSS
Housing material: Aluminium or 316SS
Housing protection IP66/68
Nominal pressure 40bar
Marine certificates (DNV-GL, LR, BV, PRS)
Accuracy 0,075% (0,05% on request)

Image

ELECTRIC LEVEL SWITCH- KIMRAY

Process Connection: Connection 1½” and 2” NPT
Operating Temperature: -40° to 350°F (316 Stainless Steel float) -40° to 200°F (poly float)
Minimum Specific Gravity: 0.4 (measured in water)
Elastomers FKM
Vessel Pressure Up to 2000 psig (316 Stainless Steel float) Up to 5000 psig (poly float)
Body Material: 316 stainless steel
Certifications: CSA, NEMA 4X Explosion Proof
Class I, Groups A, B, C, D Class II, Groups E, F, G, Class III Class I, Zone 1, AEx d llC, Ex d llC (Stainless Steel float only) Additional seal not required Electrical Rating Standard: 0.83 @ 120vac 2A @ 50VDC 3A MAXIMUM PWR: 3W MIN, 100W MAX Low Power: 0.2A @ 120VAC 1A @ 25VDC 1A MAXIMUM PWR: 25W MAX
Pice: CALL

Image

Liquid Level Switch - MODEL: BCL

Model BCL vertical float-operated level controllers are designed for control of water level in steam boilers and other vessels and storage tanks.
OPERATION
A float with a mounted magnet slides in dependance on the change of level. The magnet slides in a non-magnetic stainless steel tube and controls magnetic switches, arranged along the tube, by either breaking or making the corresponding circuit connected to feed pump, signal unit or fuel supply.
SPECIFICATION
Maximum permissible working pressure 10 Bar,16 Bar,25 Bar,30 Bar,50 Bar
Maximum permissible working temperature 250oC Magnetic switch bi-stable Switch maximum permissible loas AC 250V. 2A
Maximum number of switches 6. Minimum distance between two switchings 15mm
Maximum distance between high and low level 170mm or 320mm